Magnetic discontinuity (mt)

Глоссарий терминов по технологиям неразрушающего контроля (NDT)
    This refers to a break in the magnetic uniformity of the part – a sudden change in permeability. a magnetic discontinuity may not be related to any actual physical break in the metal, but it may produce a magnetic particle indication.




Uniformity, английский

Permeability, английский
  1. Perméabilité

  2. The ease with which a fluid flows through a porous material (wood) in response to pressure.

  3. A measure of the ease with which water penetrates a material.

  4. The relationship of flow per unit area to differential pressure across a filter medium.

  5. (of a membrane) the ability to allow some substances to pass through

  6. Проницаемость о ~ to heat теплопроницаемость ~ of soil проницаемость грунта air ~ воздухопроницаемость

  7. The state or quality of being penetrable by fluids or gases.

  8. The specific permeability, k (in m? ) is often referred to simply as

  9. The capacity of a solid substance (such as rock) to transmit a fluid. the degree of permeability depends on the number, size, and shape of the pores and/or fractures in the rock and their interconnections. it is measured by the time it takes a fluid of standard viscosity to move a given distance. the unit of permeability is the darcy.

  10. The capacity of a porous rock to transmit fluids.

  11. A measure of a material’s ability to align its magnetic domains in response to an applied magnetic field.

  12. A measure of the ease with which a fluid flows through the connecting pore spaces of rock or cement. the unit of measurement is the millidarcy.


Discontinuity, английский
  1. Разрывность (течения, кривой)

  2. Разрыв (непрерывности); нарушение сплошности; перегиб кривой; разрезность {конструкции) о ~

  3. [stratigraphy] any interruption in sedimentation, whatever its cause or length, usually a manifestation of nondeposition and accompanying erosion; an unconformity. gg part 629 - glossary 629-24 (430-vi-nssh, 2008)

  4. An interruption in the normal physical structure or configuration of a part such as cracks, laps, seams, inclusions, porosity. a discontinuity may or may not affect the usefulness of a part. see defect.

  5. Interruption in the physical structure or configuration of a test object. after nondestructive testing, a discontinuity indication may be interpreted to be a defect. compare defect; indication. discontinuity, artificial: reference discontinuity such as hole, indentation, crack, groove, or notch introduced into a reference standard to provide accurately reproducible indications for determining test sensitivity levels.

  6. Interruption in the physical structure or configuration of a test object. after nondestructive testing, a discontinuity indication can be interpreted to be a defect.4,7 compare defect; indication. discontinuity, artificial: reference discontinuity such as hole, indentation, crack, groove or notch introduced into a reference standard to provide accurately reproducible indications for determining test sensitivity levels.4 discontinuity, inherent: material anomaly originating from solidification of cast metal. pipe and nonmetallic inclusions are the most common inherent discontinuity and can lead to other types of discontinuities in fabrication.2,5 discontinuity, primary processing: discontinuity produced from the hot or cold working of an ingot into forgings, rods, bars and other shapes.2,5 discontinuity, secondary processing: discontinuity produced during machining, grinding, heat treating, plating or other finishing operations.2,5 discontinuity, service induced: discontinuity caused by the intended use of the part.

  7. Intentional or unintentional interruption in the physical structure or configuration of a part.1,4 after nondestructive testing, unintentional discontinuities interpreted as detrimental in the host object may be called flaws or defects. compare defect, dislocation and indication.1 discontinuity, artificial: reference discontinuities such as holes, indentations, cracks, grooves or notches that are introduced into a reference standard to provide accurately reproducible indications for determining sensitivity levels.1 discontinuity, primary processing: in metals processing, a material anomaly produced from the hot or cold working of an ingot into forgings, rod and bar.1 discontinuity, service induced: material anomaly caused by the intended use of the part.1 display resolution, thermal: precision with which an instrument displays its assigned measurement parameter (temperature), usually expressed in degrees, tenths of degrees, hundredths of degrees and so forth.3

  8. Interruption in the physical structure or configuration of a test object. after nondestructive testing, a discontinuity indication may be interpreted as a defect. compare anomaly; defect; indication. drift (electronic): change in output reading of an instrument, usually due to temperature change.

  9. Interruption in the physical structure or configuration of a test object. after nondestructive testing, a discontinuity indication may be interpreted as a defect. compare anomaly; defect; indication. discontinuity, artificial: reference anomaly such as hole, indentation, crack, groove, or notch introduced into a reference standard to provide accurately reproducible indications for determining test sensitivity levels. see also known discontinuity standard. discontinuity, inherent: material anomaly originating from solidification of metal. pipe, banding, and nonmetallic inclusions are the most common inherent discontinuities and can lead to other types of discontinuities in fabrication. discontinuity, primary processing: discontinuity produced from the hot or cold working of an ingot into forgings, rods, bars, and other shapes. glossary d-e 497 discontinuity, secondary processing: discontinuity produced during machining, grinding, heat treating, plating, or other finishing operations. discontinuity, service induced: discontinuity caused by the intended use of the part. see also brittle crack propagation; creep; ductile crack propagation; fatigue crack propagation.

  10. Interruption in the physical structure or configuration of a test object. after nondestructive testing, a discontinuity indication can be interpreted to be a flaw or a defect.10 compare defect; indication.5,6 discontinuity, artificial: reference discontinuity such as hole, indentation, crack, groove, or notch introduced into a reference standard to provide accurately reproducible indications for determining sensitivity levels.4

  11. Interruption in the physical structure or configuration of a test object. after nondestructive testing, a discontinuity indication can be interpreted to be a flaw or a defect.10 compare defect; indication.


Indication, английский
  1. Индикация

  2. A situation or sign which suggests that a specific treatment should be given or that a condition has a particular cause  sulpha drugs have been replaced by antibiotics in many indications.  contraindication

  3. (1) notice given by a dealer (through autex) or customer of an interest in buying or selling stock, sometimes including specific volume and price; (2) approximation of where a specialist sees buy and sell interest to tighten the range to an opening price.

  4. Выражение интереса (бирж.)

  5. In nondestructive inspection, a response or evidence of a response, that requires interpretation to determine its significance.

  6. Nondestructive test response that requires interpretation to determine its relevance. these include such things as meter deflections, shadows on radiographs, blips on screens, or localized discolorations on surfaces. see also defect; discontinuity; indication, false; indication, nonrelevant. indication, discontinuity: visible evidence of a material discontinuity. subsequent interpretation is required to determine the significance of an indication. indication, false: test indication that could be interpreted as originating from a discontinuity where no discontinuity exists. compare defect; ghost; indication, nonrelevant. false indications are an economic liability for inspection because they must be investigated. indication, nonrelevant: indication due to misapplied or improper testing. may also be an indication caused by an actual discontinuity that does not affect the usability of the test object (a change of section, for instance). indication, relevant: indication from a discontinuity (as opposed to a nonrelevant indication) requiring evaluation by a qualified inspector, typically with reference to an acceptance standard, by virtue of the discontinuity’s size, shape, orientation, or location.

  7. Nondestructive test response that requires interpretation to determine its relevance.4 see also defect; discontinuity; false indication; nonrelevant indication. indication, nonrelevant: indication that has no relation to a discontinuity that might constitute a defect.1 test response caused by geometry or by a physical condition that is not a discontinuity. indication, relevant: indication from a discontinuity (as opposed to a false indication) requiring evaluation by a qualified inspector, typically with reference to an acceptance standard, by virtue of the discontinuity’s size or location.1

  8. Nondestructive test response that requires interpretation to determine its relevance. compare defect; discontinuity; indication, false; indication, nonrelevant. indication, false: (1) test indication that could be interpreted as originating from a discontinuity but that actually originates where no discontinuity exists in the test object. (2) indication due to misapplied or improper testing. compare indication, nonrelevant; defect. indication, nonrelevant: indication that has no relation to a discontinuity that might constitute a defect. test response caused by geometry or by a physical condition that is not a discontinuity (a change of section, for instance). indication, relevant: indication from a discontinuity (as opposed to a false indication) requiring evaluation by a qualified inspector, typically with reference to an acceptance standard, by virtue of the discontinuity’s size or location.

  9. Nondestructive test response that requires interpretation to determine its relevance. compare defect; discontinuity. see also indication, false; indication, nonrelevant. indication, false: (1) test indication that could be interpreted as originating from a discontinuity but that actually originates where no discontinuity exists in the test object. (2) indication due to misapplied or improper testing. compare indication, nonrelevant. indication, nonrelevant: indication that has no relation to a discontinuity that might constitute a defect. test response caused by geometry or by a physical condition that is not a discontinuity (a change of section, for instance). indication, relevant: indication from a discontinuity (as opposed to a false indication) requiring evaluation by a qualified inspector, typically with reference to an acceptance standard, by virtue of the discontinuity’s size or location.

  10. Nondestructive test equipment response to a discontinuity that requires interpretation to determine its relevance.4 in magnetic particle testing, a visible accumulation of magnetic particles that serves as evidence of a magnetic leakage field.

  11. Defect, discontinuity, false indication and nonrelevant indication. induced current magnetization: noncontact means for testing delicate ring shaped objects for circumferential discontinuities. the technique is based on the fact that a time varying current passing through an internal conductor, often a soft iron or laminated core, self-induces an encircling magnetic field. this time varying magnetic field will induce a secondary current circling through the ring. this secondary current then self-induces the toroidal magnetic field used for testing.

  12. Nondestructive test equipment response to a reflector, requiring interpretation to determine its relevance. compare crack; defect; discontinuity; indication, false.10 indication, discontinuity: visible evidence of a material discontinuity. subsequent interpretation is required to determine the indication’s significance.10 indication, false: test indication that originates where no discontinuity exists in the test object. compare defect; indication, nonrelevant.10 indication, nonrelevant: indication possibly caused by an actual discontinuity that does not affect the usability of the test object (a change of section, for instance) or that is smaller than a relevant indication. compare indication, false and indication, relevant.10 indication, relevant: indication from a discontinuity (as opposed to a nonrelevant indication) requiring evaluation by a qualified inspector, typically with reference to an acceptance standard, by virtue of the discontinuity’s size, shape, orientation or location. compare indication, nonrelevant.10,19


Single-phase alternating current, английский
    This term refers to a simple current, alternating in direction. commercial single-phase current follows a sine wave. such a current requires only two conductors for its circuit. most common commercial frequencies are 25,50 and 60 cycles per second.


Remnant magnetism, английский
    This is the term applied to the magnetism remaining in a magnetic circuit after the magnetizing force is removed.