Magnetic particle testing

Глоссарий по неразрушающему контролю в авиации
    Nondestructive test method using magnetic leakage fields and indication materials to disclose surface and near-surface discontinuities.




Nondestructive, английский
  1. Неразрушающий

  2. Неразрушающий (об испытаниях и т.п.)


Indication, английский
  1. Индикация

  2. A situation or sign which suggests that a specific treatment should be given or that a condition has a particular cause  sulpha drugs have been replaced by antibiotics in many indications.  contraindication

  3. (1) notice given by a dealer (through autex) or customer of an interest in buying or selling stock, sometimes including specific volume and price; (2) approximation of where a specialist sees buy and sell interest to tighten the range to an opening price.

  4. Выражение интереса (бирж.)

  5. In nondestructive inspection, a response or evidence of a response, that requires interpretation to determine its significance.

  6. Nondestructive test response that requires interpretation to determine its relevance. these include such things as meter deflections, shadows on radiographs, blips on screens, or localized discolorations on surfaces. see also defect; discontinuity; indication, false; indication, nonrelevant. indication, discontinuity: visible evidence of a material discontinuity. subsequent interpretation is required to determine the significance of an indication. indication, false: test indication that could be interpreted as originating from a discontinuity where no discontinuity exists. compare defect; ghost; indication, nonrelevant. false indications are an economic liability for inspection because they must be investigated. indication, nonrelevant: indication due to misapplied or improper testing. may also be an indication caused by an actual discontinuity that does not affect the usability of the test object (a change of section, for instance). indication, relevant: indication from a discontinuity (as opposed to a nonrelevant indication) requiring evaluation by a qualified inspector, typically with reference to an acceptance standard, by virtue of the discontinuity’s size, shape, orientation, or location.

  7. Nondestructive test response that requires interpretation to determine its relevance.4 see also defect; discontinuity; false indication; nonrelevant indication. indication, nonrelevant: indication that has no relation to a discontinuity that might constitute a defect.1 test response caused by geometry or by a physical condition that is not a discontinuity. indication, relevant: indication from a discontinuity (as opposed to a false indication) requiring evaluation by a qualified inspector, typically with reference to an acceptance standard, by virtue of the discontinuity’s size or location.1

  8. Nondestructive test response that requires interpretation to determine its relevance. compare defect; discontinuity; indication, false; indication, nonrelevant. indication, false: (1) test indication that could be interpreted as originating from a discontinuity but that actually originates where no discontinuity exists in the test object. (2) indication due to misapplied or improper testing. compare indication, nonrelevant; defect. indication, nonrelevant: indication that has no relation to a discontinuity that might constitute a defect. test response caused by geometry or by a physical condition that is not a discontinuity (a change of section, for instance). indication, relevant: indication from a discontinuity (as opposed to a false indication) requiring evaluation by a qualified inspector, typically with reference to an acceptance standard, by virtue of the discontinuity’s size or location.

  9. Nondestructive test response that requires interpretation to determine its relevance. compare defect; discontinuity. see also indication, false; indication, nonrelevant. indication, false: (1) test indication that could be interpreted as originating from a discontinuity but that actually originates where no discontinuity exists in the test object. (2) indication due to misapplied or improper testing. compare indication, nonrelevant. indication, nonrelevant: indication that has no relation to a discontinuity that might constitute a defect. test response caused by geometry or by a physical condition that is not a discontinuity (a change of section, for instance). indication, relevant: indication from a discontinuity (as opposed to a false indication) requiring evaluation by a qualified inspector, typically with reference to an acceptance standard, by virtue of the discontinuity’s size or location.

  10. Nondestructive test equipment response to a discontinuity that requires interpretation to determine its relevance.4 in magnetic particle testing, a visible accumulation of magnetic particles that serves as evidence of a magnetic leakage field.

  11. Defect, discontinuity, false indication and nonrelevant indication. induced current magnetization: noncontact means for testing delicate ring shaped objects for circumferential discontinuities. the technique is based on the fact that a time varying current passing through an internal conductor, often a soft iron or laminated core, self-induces an encircling magnetic field. this time varying magnetic field will induce a secondary current circling through the ring. this secondary current then self-induces the toroidal magnetic field used for testing.

  12. Nondestructive test equipment response to a reflector, requiring interpretation to determine its relevance. compare crack; defect; discontinuity; indication, false.10 indication, discontinuity: visible evidence of a material discontinuity. subsequent interpretation is required to determine the indication’s significance.10 indication, false: test indication that originates where no discontinuity exists in the test object. compare defect; indication, nonrelevant.10 indication, nonrelevant: indication possibly caused by an actual discontinuity that does not affect the usability of the test object (a change of section, for instance) or that is smaller than a relevant indication. compare indication, false and indication, relevant.10 indication, relevant: indication from a discontinuity (as opposed to a nonrelevant indication) requiring evaluation by a qualified inspector, typically with reference to an acceptance standard, by virtue of the discontinuity’s size, shape, orientation or location. compare indication, nonrelevant.10,19


Magnetic saturation, английский
  1. That degree of magnetization where a further increase in magnetizing force produces no significant increase in magnetic flux density in an object. in this region, the permeability of the material is the same as that found in air or nonmagnetic materials.

  2. Result of complete domain alignment where an increase in the coercive field h produces no change in flux density b.


Magnetic flux meter, английский
    Electronic device for measuring magnetic flux leakage. included are items such as gauss meters and hall effect field meters.